Zander Aachen TALOS MODBUS

  1. Products
  2. Zander Aachen
  3. Zander Aachen TALOS MODBUS
Brand:

Zander Aachen

Product Code:

TALOS MODBUS

Description:

unction of the TALOS Modbus RTU interface


The TALOS Modbus variants provide a Modbus RTU interface via which the following diagnostic information can be read out from the device.



  • Status of inputs and outputs

  • Currently loaded configuration

  • Currently parameterized delay times for the three safe outputs

  • Currently displayed error numbers



In the event of an error message on the device, e.g. due to the detection of a cross-circuit, the error can also be acknowledged via the MODBUS interface depending on the type of error (see operating manual).


Each TALOS variant is also available in the Modbus RTU version.


The Modbus version enables diagnostic information to be transmitted from the TALOS via the fieldbus. For this purpose, the device does not have to be configured and can be connected directly to the fieldbus.


The connection to the fieldbus enables automatic monitoring of the controller and its switching states, for example for documentation as well as centralized diagnostics.


The existing functionalities of the TALOS remain unchanged: Diagnostics via the built-in display is also still possible without restriction with the Modbus variant.

You can review the specification and details of the Zander Aachen TALOS MODBUS TALOS MODBUS below. To get a quotation, please fill in the online quotation form. One of our staff will respond your request as soon as possible.

  • Product Details
    Feature Value
    TB-Modbus Variant with parameterizable time delays from 0 to 990 seconds and Modbus RTU interface
    Order No. plug-in screw terminals 474650
    Order No. incl. plug-in spring-cage terminals 475650
    TB-Modbus m Variant with parameterizable time delays from 0 to 990 minutes and Modbus RTU interface
    Order No. plug-in screw terminals 474651
    Order No. incl. plug-in spring-cage terminals 475651
    TB-Modbus h Variant with parameterizable time delays from 0 to 99 hours and Modbus RTU interface
    Order No. plug-in screw terminals 474652
    Order No. incl. plug-in spring-cage terminals 475652
  • talos-modbus-kurzanleitung.pdf

  • Datasheets for Zander Aachen

    Country & Language
    Filename
    Download Link
    United States (English)

    zander_aachen_product_catalogue_c04c02.pdf

    Download

Related Products

Zander Aachen SRTC Time-delayed Safety Extension Module
Zander Aachen SRTC Time-delayed Safety Extension Module
ZANDER AACHEN - SRTC
See details
Zander Aachen ZCode-LR 941149 Actuator
Zander Aachen ZCode-LR 941149 Actuator
ZANDER AACHEN - ZCode-LR 941149
Zander Aachen ZStop S
Zander Aachen ZStop S
ZANDER AACHEN - ZStop S
Zander Aachen ZStop SE
Zander Aachen ZStop SE
ZANDER AACHEN - ZStop SE
Company
Contact & Support
Copyright © 2024 Kraftindustrie. All rights reserved.